N2XCH

Power cable, XLPE insulated, copper conductor, concentric copper conductor, halogen free, flame retardant

N2XCH

According to VDE 0276 part 604 and 627.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    N2XCH 2X1,5 RE/1,5 2 1.5 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    1.5 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    2
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    1.5 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    Yes
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    Yes
    Outer diameter approx.
    11 mm
    Min. permitted bending radius, stationary application/permanent installation
    132 mm
    Weight
    150.51
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 90 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 52
    Product No. Individual length Pallet unit Packing
    229246 Cut length Ring, Drum
    N2XCH 2X2,5 RE/2,5 2 2.5 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    2.5 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    2
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    2.5 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    Yes
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    Yes
    Outer diameter approx.
    12 mm
    Min. permitted bending radius, stationary application/permanent installation
    144 mm
    Weight
    190.02
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 90 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 80
    Product No. Individual length Pallet unit Packing
    229253 Cut length Ring, Drum
    N2XCH 3X1,5 RE/1,5 3 1.5 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    1.5 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    3
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    1.5 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking conductors
    Yes
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    Yes
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    Yes
    Outer diameter approx.
    11 mm
    Min. permitted bending radius, stationary application/permanent installation
    132 mm
    Weight
    166.65
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 90 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 66
    Product No. Individual length Pallet unit Packing
    229260 Cut length Ring, Drum
    N2XCH 3X2,5 RE/2,5 3 2.5 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    2.5 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Round
    Number of cores
    3
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    2.5 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Black
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    Yes
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    Yes
    Outer diameter approx.
    12 mm
    Min. permitted bending radius, stationary application/permanent installation
    144 mm
    Weight
    214.16
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 90 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 104
    Product No. Individual length Pallet unit Packing
    229277 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "N2XCH"