PVILDS-AL-S

Power cable, PVC insulated, aluminium conductor, PVC outersheath, lead free

PVILDS-AL-S

according HD 603 3E.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    PVILDS-AL-S 4X50 SM BF 4 50 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    50 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    29 mm
    Min. permitted bending radius, stationary application/permanent installation
    360 mm
    Weight
    1,181.1
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Aluminium 580
    Product No. Individual length Pallet unit Packing
    292363 Cut length Ring, Drum
    PVILDS-AL-S 4X95 SM BF 4 95 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    38 mm
    Min. permitted bending radius, stationary application/permanent installation
    456 mm
    Weight
    2,012.2
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Aluminium 1102
    Product No. Individual length Pallet unit Packing
    282531 Cut length Ring, Drum
    PVILDS-AL-S 4X150 SM BF 4 150 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    46 mm
    Min. permitted bending radius, stationary application/permanent installation
    576 mm
    Weight
    2,958.4
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Aluminium 1740
    Product No. Individual length Pallet unit Packing
    282616 Cut length Ring, Drum
    PVILDS-AL-S 4X240 SM BF 4 240 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Grey
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    56 mm
    Min. permitted bending radius, stationary application/permanent installation
    732 mm
    Weight
    4,543.8
    Max. conductor temperature
    70 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    160 °C
    Insulation
    PVC
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Aluminium 2784
    Product No. Individual length Pallet unit Packing
    282692 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "PVILDS-AL-S"