N2XSY 20kV

Medium-voltage cable, XLPE insulated, copper conductor, PVC outersheath

N2XSY 20kV

according VDE 0276 part 620.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    N2XSY 20kV 1X70 RM/16 20kV 1 70 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    70 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    32 mm
    Min. permitted bending radius, stationary application/permanent installation
    480 mm
    Weight
    1,377.7
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 854
    Product No. Individual length Pallet unit Packing
    241422 Cut length Ring, Drum
    N2XSY 20kV 1X95 RM/16 20kV 1 95 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    34 mm
    Min. permitted bending radius, stationary application/permanent installation
    510 mm
    Weight
    1,655.1
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 1094
    Product No. Individual length Pallet unit Packing
    241446 Cut length Ring, Drum
    N2XSY 20kV 1X120 RM/16 20kV 1 120 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    120 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    35 mm
    Min. permitted bending radius, stationary application/permanent installation
    525 mm
    Weight
    1,905.3
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 1334
    Product No. Individual length Pallet unit Packing
    241460 Cut length Ring, Drum
    N2XSY 20kV 1X150 RM/25 20kV 1 150 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    37 mm
    Min. permitted bending radius, stationary application/permanent installation
    555 mm
    Weight
    2,272.9
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 1723
    Product No. Individual length Pallet unit Packing
    241484 Cut length Ring, Drum
    N2XSY 20kV 1X240 RM/25 20kV 1 240 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    41 mm
    Min. permitted bending radius, stationary application/permanent installation
    615 mm
    Weight
    3,202.2
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 2587
    Product No. Individual length Pallet unit Packing
    241521 Cut length Ring, Drum
    N2XSY 20kV 1X300 RM/25 20kV 1 300 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    300 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    43 mm
    Min. permitted bending radius, stationary application/permanent installation
    645 mm
    Weight
    3,795.6
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 3163
    Product No. Individual length Pallet unit Packing
    241545 Cut length Ring, Drum
    N2XSY 20kV 1X400 RM/35 20kV 1 400 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    400 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    46 mm
    Min. permitted bending radius, stationary application/permanent installation
    690 mm
    Weight
    4,707
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 4234
    Product No. Individual length Pallet unit Packing
    241569 Cut length Ring, Drum
    N2XSY 20kV 1X500 RM/35 20kV 1 500 mm²
    Conductor material
    Copper
    Conductor surface
    Bare
    Nominal cross section conductor
    500 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    49 mm
    Min. permitted bending radius, stationary application/permanent installation
    735 mm
    Weight
    5,755.2
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    12 kV
    Nominal voltage U
    20 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 5194
    Product No. Individual length Pallet unit Packing
    235964 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "N2XSY 20kV"