NA2XSY 30kV

Medium-voltage cable, XLPE insulated, aluminium conductor, PVC outersheath

NA2XSY 30kV

According to VDE 0276 part 620.

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    NA2XSY 30kV 1X50 RM/16 30kV 1 50 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    50 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    35 mm
    Min. permitted bending radius, stationary application/permanent installation
    525 mm
    Weight
    1,092.9
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 182, Aluminium 145
    Product No. Individual length Pallet unit Packing
    234882 Cut length Ring, Drum
    NA2XSY 30kV 1X70 RM/16 30kV 1 70 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    70 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    37 mm
    Min. permitted bending radius, stationary application/permanent installation
    555 mm
    Weight
    1,206
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 182, Aluminium 203
    Product No. Individual length Pallet unit Packing
    234912 Cut length Ring, Drum
    NA2XSY 30kV 1X95 RM/16 30kV 1 95 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    39 mm
    Min. permitted bending radius, stationary application/permanent installation
    585 mm
    Weight
    1,362.4
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 182, Aluminium 276
    Product No. Individual length Pallet unit Packing
    234943 Cut length Ring, Drum
    NA2XSY 30kV 1X120 RM/16 30kV 1 120 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    120 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    40 mm
    Min. permitted bending radius, stationary application/permanent installation
    600 mm
    Weight
    1,485.9
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 182, Aluminium 348
    Product No. Individual length Pallet unit Packing
    234974 Cut length Ring, Drum
    NA2XSY 30kV 1X150 RM/25 30kV 1 150 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    150 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    41 mm
    Min. permitted bending radius, stationary application/permanent installation
    615 mm
    Weight
    1,669.2
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 283, Aluminium 435
    Product No. Individual length Pallet unit Packing
    235001 Cut length Ring, Drum
    NA2XSY 30kV 1X185 RM/25 30kV 1 185 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    43 mm
    Min. permitted bending radius, stationary application/permanent installation
    645 mm
    Weight
    1,840.9
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 283, Aluminium 537
    Product No. Individual length Pallet unit Packing
    235032 Cut length Ring, Drum
    NA2XSY 30kV 1X240 RM/25 30kV 1 240 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    240 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    46 mm
    Min. permitted bending radius, stationary application/permanent installation
    690 mm
    Weight
    2,073.1
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 283, Aluminium 696
    Product No. Individual length Pallet unit Packing
    235063 Cut length Ring, Drum
    NA2XSY 30kV 1X300 RM/25 30kV 1 300 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    300 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    48 mm
    Min. permitted bending radius, stationary application/permanent installation
    720 mm
    Weight
    2,320.7
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Copper 283, Aluminium 870
    Product No. Individual length Pallet unit Packing
    259779 Cut length Ring, Drum
    NA2XSY 30kV 1X400 RM/35 30kV 1 400 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    400 mm²
    Conductor category
    Class 2 = stranded
    Shape of conductor
    Round
    Number of cores
    1
    Core identification
    None
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    Yes
    Outer semi-conducting layer
    Yes
    Screen
    Yes
    Concentric conductor
    None
    Armouring
    No
    Material outer sheath
    Polyvinyl chloride (PVC)
    Specification material outer sheath
    Other
    Colour outer sheath
    Red
    Conductive coating
    No
    Longitudinal water blocking conductors
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Fca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-1-2
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    51 mm
    Weight
    2,755.8
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    18 kV
    Nominal voltage U
    30 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    15 x Außen-Ø
    Metal number
    Aluminium 1160, Copper 394
    Product No. Individual length Pallet unit Packing
    361106 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "NA2XSY 30kV"