A2XCWY Eca

Starkstromkabel, VPE-isoliert mit Al-Leitern und konzentrischem Cu-Leiter in CEANDER-Form

A2XCWY Eca

  • Variants
  • Downloads
  • Shorter and longer lengths
  • Number of cores

    Cross section conductor

    Technical features Product
    A2XCWY Eca 3X 95 SE/59 3 95 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    3
    Core identification according to HD 308 S2
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    59 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Cable geometry
    Conductive coating
    No
    Longitudinal water blocking conductors
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    34 mm
    Min. permitted bending radius, stationary application/permanent installation
    396 mm
    Weight
    2,022.3
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    Suitable as installation cable
    Certified for shipboard application
    Suitable as medium-voltage cable
    Suitable as high-voltage cable
    Certified as airport lighting cable
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 660, Aluminium 827
    Product No. Individual length Pallet unit Packing
    300242 Cut length Ring, Drum
    A2XCWY Eca 3X185 SE/116 3 185 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    3
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    116 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Conductive coating
    No
    Longitudinal water blocking conductors
    Yes
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    44 mm
    Min. permitted bending radius, stationary application/permanent installation
    528 mm
    Weight
    3,622.5
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 1236, Aluminium 1610
    Product No. Individual length Pallet unit Packing
    299423 Cut length Ring, Drum
    A2XCWY Eca 3X300 SE/116 3 300 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    300 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    3
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    116 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    53 mm
    Min. permitted bending radius, stationary application/permanent installation
    624 mm
    Weight
    4,899.4
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 1236, Aluminium 2610
    Product No. Individual length Pallet unit Packing
    299539 Cut length Ring, Drum
    A2XCWY Eca 4X 95 SE/59 4 95 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    95 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    59 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Conductive coating
    No
    Longitudinal water blocking conductors
    Yes
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    38 mm
    Weight
    2,416.4
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 660, Aluminium 1102
    Product No. Individual length Pallet unit Packing
    353149 Cut length Ring, Drum
    A2XCWY Eca 4X185 SE/116 4 185 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    185 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    116 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    50 mm
    Weight
    4,433.5
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 1236, Aluminium 2146
    Product No. Individual length Pallet unit Packing
    353187 Cut length Ring, Drum
    A2XCWY Eca 4X300 SE/116 4 300 mm²
    Conductor material
    Aluminium
    Conductor surface
    Bare
    Nominal cross section conductor
    300 mm²
    Conductor category
    Class 1 = solid
    Shape of conductor
    Sector-shaped
    Number of cores
    4
    Core identification
    Colour
    Laminated sheath
    No
    Fibre optic elements
    No
    Protective conductor
    No
    Inner semi-conducting layer
    No
    Outer semi-conducting layer
    No
    Screen
    No
    Concentric conductor
    Copper
    Nominal cross section concentric conductor
    116 mm²
    Armouring
    No
    Material outer sheath
    Polyolefin
    Specification material outer sheath
    Polyethylene (PE)
    Colour outer sheath
    Orange
    Conductive coating
    No
    Longitudinal water blocking screen
    No
    Reaction-to-fire according to EN 13501-6: Class
    Eca
    Halogen free (acc. EN 60754-1/2)
    No
    Flame retardant
    In accordance with IEC/EN 60332-3-24
    Low smoke (acc. EN 61034-2)
    No
    Outer diameter approx.
    60 mm
    Weight
    6,169.4
    Max. conductor temperature
    90 °C
    Permitted cable outer temperature during assembling/handling
    -5 <=> 70 °C
    Nominal voltage U0
    0.6 kV
    Nominal voltage U
    1 kV
    max. short circuit temperature
    250 °C
    Insulation
    XLPE (VPE)
    Minimum bending radius
    12 x Außen-Ø
    Metal number
    Copper 1236, Aluminium 3480
    Product No. Individual length Pallet unit Packing
    353262 Cut length Ring, Drum
  • Title Language
    Datasheet
    Declaration of Performance
  • We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.

    If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.

    To shorter and longer lengths "A2XCWY Eca"