H07Z-R Dca
according VDE 0285-525-3-41.
- Variants
- Downloads
- Shorter and longer lengths
-
Number of cores
Cross section conductor
Technical features Product H07Z-R Dca Dca 10 1 10 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 10 mm²
- Conductor Diameter
- 10 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 1.83
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Black
- Protective conductor
- No
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 6 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 105.96
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 96
Product No. Individual length Pallet unit Packing 597963 Cut length Ring, Drum 593392 100 m 6,000 Ring H07Z-R Dca Dca 16 1 16 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 16 mm²
- Conductor Diameter
- 16 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 1.15
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Green/yellow
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 7 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 160.48
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Paletteinheit
- 6,600 m
- Außendurchmesser
- 390 mm
- Kerndurchmesser
- 200 mm
- Höhe
- 52 mm
- Bruttogewicht pro Paletteinheit
- 1,081.97 kg
- Metal number
- Copper 154
Product No. Individual length Pallet unit Packing 593422 100 m 6,600 Ring 597987 1000 m 6,000 Drum H07Z-R Dca Dca 25 1 25 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 25 mm²
- Conductor Diameter
- 25 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.727
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Green/yellow
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 9 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 251.65
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Paletteinheit
- 4,200 m
- Bruttogewicht pro Paletteinheit
- 1,079.73 kg
- Metal number
- Copper 240
Product No. Individual length Pallet unit Packing 593453 100 m 4,200 Ring 598007 1000 m 4,000 Drum H07Z-R Dca Dca 35 1 35 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 35 mm²
- Conductor Diameter
- 35 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.524
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 10 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 339.33
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 336
Product No. Individual length Pallet unit Packing 593484 Cut length Ring, Drum H07Z-R Dca Dca 50 1 50 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 50 mm²
- Conductor Diameter
- 50 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.387
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 11 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 461.41
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 480
Product No. Individual length Pallet unit Packing 593552 Cut length Ring, Drum H07Z-R Dca Dca 70 1 70 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 70 mm²
- Conductor Diameter
- 70 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.268
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 13 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 653.47
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 672
Product No. Individual length Pallet unit Packing 593583 Cut length Ring, Drum H07Z-R Dca Dca 95 1 95 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 95 mm²
- Conductor Diameter
- 95 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.193
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 15 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 901.59
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 912
Product No. Individual length Pallet unit Packing 593613 Cut length Ring, Drum H07Z-R Dca Dca 120 1 120 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 120 mm²
- Conductor Diameter
- 120 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.153
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 16 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 1,117.4
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 1152
Product No. Individual length Pallet unit Packing 593644 Cut length Ring, Drum H07Z-R Dca Dca 150 1 150 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 150 mm²
- Conductor Diameter
- 150 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.124
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 18 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 1,390.1
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 1440
Product No. Individual length Pallet unit Packing 593712 Cut length Ring, Drum H07Z-R Dca Dca 185 1 185 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 185 mm²
- Conductor Diameter
- 185 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.099
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 21 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 1,725.9
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 1776
Product No. Individual length Pallet unit Packing 593743 Cut length Ring, Drum H07Z-R Dca Dca 240 1 240 mm² - Conductor material
- Copper
- Nominal cross section conductor
- 240 mm²
- Conductor Diameter
- 240 mm
- Conductor category
- Class 2 = stranded
- Conductor resistance at 20 °C
- 0.075
- Number of cores
- 1
- Core insulation material
- Polyolefin
- Core identification according to HD 308 S2
- Yes
- Core colour
- Protective conductor
- Yes
- Max. conductor temperature
- 70 °C
- Screen
- No
- Armouring/reinforcement
- None
- Material outer sheath
- None
- Colour outer sheath
- Colourless
- Reaction-to-fire according to EN 13501-6: Class
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production
- s1a
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
- Reaction-to-fire according to EN 13501-6: Acidity
- a1
- Halogen free (acc. EN 60754-1/2)
- Yes
- Flame retardant
- In accordance with IEC/EN 60332-1-2
- Low smoke (acc. EN 61034-2)
- Yes
- Outer diameter approx.
- 23 mm
- Permitted cable outer temperature during assembling/handling
- 5 <=> 70 °C
- Nominal voltage U0
- 450 V
- Nominal voltage U
- 750 V
- Shape of conductor
- Round
- Suitable as installation cable
- Yes
- Certified for shipboard application
- No
- Suitable as medium-voltage cable
- No
- Suitable as high-voltage cable
- No
- Certified as airport lighting cable
- No
- Weight
- 2,265.3
- Minimum bending radius
- 4 x Außen-Ø
- max. short circuit temperature
- 250 °C
- Metal number
- Copper 2304
Product No. Individual length Pallet unit Packing 593774 Cut length Ring, Drum -
We can supply you with shorter lengths and longer lengths of the many cables our company offers, which are available right now in the lengths listed. An additional advantage for you: We offer a price discount on each agreed base price/price without metal on our shorter and longer length cables when purchasing the complete length.
To shorter and longer lengths "H07Z-R Dca"
If you have any queries in this regard, please feel free to get in touch with your usual contact. Together, we will find the right cable solution for your application. You can directly access our current offers for shorter/longer lengths here.